Features
* High performance true double conversion On Line UPS 6-20KVA
* Rack / tower convertible cabinet-12U for 6/10KVA, 19U for 20KVA
* External battery bank (optional) to extend back-up time
* Microprocessor control guarantees high reliability
* Low heat dissipation in long time operation
* Input THDi < 5% / Output THD < 2%
* Emergency power-off function (EPO)
* N+X parallel redundancy and capacity expansion (Optional)
* High efficiency mode (ECO mode)
* Fan speed control & DC start
* Output voltage regulation < 1%
* Isolation transformer (Optional)
* Automatic self-testing function
* Power management software
* Output power factor 0.9
* Maintenance bypass
MODEL | IDEAL-9306LRB-12U | |
CAPACITY | 6KVA/5.4KW | |
INPUT | ||
Phase | 1 Phase 2 Wires + Ground | |
Voltage | 208/220/230/240Vac | |
Frequency | 50Hz or 60Hz (Auto Sensing) | |
THDi | < 5% with R Full Load | |
OUTPUT | ||
Phase | 1 Phase 2 Wires + G or 1 Phase 3 Wires +G(With Isolation Transformer) | |
Voltage | 1 Phase 2 Wires +G: 208/220/230/240Vac or 1 Phase 3 Wires +G (With Isolation Transformer): 110/220Vac or 115/230Vac or 120/240Vac |
|
Voltage Regulation | +/- 1% (+/-2% with Isolation Transformer) | |
Frequency (Battery Mode) | 50Hz or 60Hz +/-0.05Hz | |
Waveform | Pure Sinewave | |
THD | < 2% (Linear Load) or <5% (Non-Linear Load) | |
Crest Ratio | 3:1 | |
EFFICIENCY | ||
To AC Mode | > 92% at Full Load and Battery Full Charged | |
To Battery Mode | > 92% at Full Load and 12VDC/Battery | |
ECO Mode | > 96% at Full Load and Battery Full Charged | |
BATTERY | ||
Voltage | 240VDC | |
Type | 12V/7AH*20pcs | Extendable |
Recharge Time | 7Hrs to 90% | Depend on Capacity of External Battery |
TRANSFER TIME | ||
Line <-> Battery | 0ms | |
Inverter <-> Bypass | 0ms | |
ECO Mode <-> Inverter | < 10ms | |
DISPLAY | ||
LED | Normal (Green), Bypass (Yellow), Fault (Red), Battery (Yellow) | |
LCD | Load Level/Battery Voltage/Battery Mode/AC Mode/Bypass Mode Information | |
AUDIBLE ALARM | ||
Battery Mode | Sounding Every 4 Seconds | |
Low Battery | Sounding Every Second | |
Overload | Sounding Twice Every Second | |
UPS Fault | Continuously Sounding | |
COMMUNICATIONS | ||
Interface(Port) | Dry Contact & USB | |
Intelligent Slot | SNMP /RS485 / AS400 | |
EPO | Emergency Power Off | |
ENVIRONMENT | ||
Temperature | 0 – 40℃ (32℉ – 104℉) | |
Humidity | 0 – 95% non-condensing | |
Acoustic Noise | < 50dB at 1M | |
PHYSICAL | ||
Dimension (W*H*D) | 440*528*630mm (12U) | |
* Product specifications are subject to change without further notice. |
There are no reviews yet.